4 - 22
PST-7000 series user’s manual – BRIEF INTRODUCTION
LED INDICATORS
Besides the LED on MSR unit there are another two LED’s on the main unit
below the 6-position electronic key on the programmable keyboard (ref. Fig. 4-8). The
right hand green LED, called as the power LED, and the left hand orange LED, called
as the Standby LED, together exhibit several different system status depending on
whether or not an UPS battery is fitted.
(a) Without an UPS battery the power LED lights to show that the system is turned
ON under presence of AC power. The standby LED indicates that AC power is
available when the system is powered off.
(b) With a UPS battery fitted:
1. The standby LED gives a steady illumination to indicate the presence of
AC power when the system is powered off. The system cannot be turned
on if the AC power fails, even when the battery is fully charged. The
power LED goes ON and the standby LED goes OFF when the system is
powered up.
2. During periods of AC power failure with the system turned on, the power
LED flashes to indicate that the system is running on battery power.
3. The power LED is turned OFF and the standby LED flashes rather fast as
the UPS battery approaches a discharged condition to remind the operator
that power will soon finish. In few seconds, the whole system will soon be
automatically turned off and both LED will be OFF.
4. In case the AC power resumes during the usage of the battery, the flashing
LED will keep on flashing for few seconds till the AC supply is
considered stable.